Command 960 - Exit From The Installer's Programming Mode; Command 961 - Reset The Control Panel To Factory Default Settings; Command 962 - Copy The Control Panel Memory To The Programming Key; Command 963 - Copy The Programming Key To The Control Panel - Bosch ICP-CC404 Installation Manual

Hide thumbs Also See for ICP-CC404:
Table of Contents

Advertisement

ICP-CC404 | Installation Guide | 2.0
2.4.3
Command 960 – Exit from the Installer's
Programming Mode
This command exits from the Installer's
Programming Mode. You can exit from the Installer's
Programming Mode from any location.
To exit from the Installer's Programming Mode:
Enter [9 6 0 #].
Two beeps sound and the system returns to the
disarmed state. When using the remote codepad, the
STAY and AWAY indicators turn off.
2.4.4
Command 961 – Reset the Control Panel to
Factory Default Settings
This command resets the control panel to factory
default values. Default values are listed throughout
this guide and in the programming sheets in
Section 22.0 on page 85. You can reset the control
panel from any location.
To reset the control panel to factory defaults:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators flash on the remote codepad to
indicate you entered Installer's Programming
Mode. The remote codepad shows the data
stored in Location 000.
2. Enter [9 6 1 #].
Two beeps sound and the system resets to the
factory default values.
2.4.5
Command 962 – Copy the Control Panel
Memory to the Programming Key
This command copies the control panel memory to
the programming key. You can only use the CC891
Programming Key with the ICP-CC404 Control
Panel.
To copy the control panel memory to the
programming key:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators flash on the remote codepad to
indicate you entered Installer's Programming
Mode. The remote codepad shows the data
stored in Location 000.
2. Connect the programming key to the
PROGRAMMING KEY pins (next to the
Auxiliary Module socket) at the top of the control
panel's printed circuit board.
3. Enter [9 6 2 #].
12
Programming
Two beeps sound after the control panel memory
is successfully copied to the programming key. A
long beep indicates that the programming key is
corrupt and must be erased to clear the corrupt
data. Refer to Section 2.4.7 Command 964 – Erase
the Programming Key on page 13 for more
information.
4. Enter command [9 6 0 #] to exit from the
Installer's Programming Mode.
The STAY and AWAY indicators turn off on the
remote codepad to indicate that the system is
disarmed.
5. Remove the programming key from the control
panel.
Failure to exit from the Installer's Programming
Mode before removing the programming key can
corrupt the programming key.
2.4.6
Command 963 – Copy the Programming
Key to the Control Panel
This command copies data from the programming
key to the control panel. You can only use the CC891
Programming Key with the ICP-CC404 Control
Panel.
To copy the programming key memory to the
control panel:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
Two beeps sound and the STAY and AWAY
indicators flash on the remote codepad to
indicate you entered Installer's Programming
Mode. The remote codepad shows the data
stored in Location 000.
2. Connect the programming key to the
PROGRAMMING KEY pins (next to the
Auxiliary Module socket) at the top of the control
panel's printed circuit board.
3. Enter [9 6 3 #].
Two beeps sound after the programming key's
data is successfully copied to the control panel. A
long beep indicates that the programming key is
corrupt and must be erased to clear the corrupt
data. Refer to Section 2.4.7 Command 964 – Erase
the Programming Key on page 13 for more
information.
4. Enter [9 6 0 #] to exit from the Installer's
Programming Mode.
The STAY and AWAY indicators turn off on the
remote codepad to indicate that the system is
disarmed.
5. Remove the programming key from the control
panel.
Failing to exit from the Installer's Programming
Mode before removing the programming key can
corrupt the programming key.
Bosch Security Systems, Inc. | 12/08 | F01U089401-02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents