System Event Memory Recall

There are two Event Memorys, one for ALL EVENTS and one for EN EVENTS. Up to 254 system
events can be recorded in event memory in chronological order. These events are with date
and time information and stored in non-volatile memory.
For Event records refer toTable 8.1, Page 66.
8.3.1

Keypad Play Back System Events

When Installer Code/Master Code function is used to play back the events, only five system
events in below table can be shown using the keypad indicators.
Event
Zone Alarm or Tamper (Zone1-8)
Tamper Alarm
STAY Arming
AWAY Arming
System Disarming
Detailed process is as below:
1.
2.
3.
Press [#] to exit from the Event Play Back Mode at anytime.
8.4

Output Process

The AMAX panel 2000 / AMAX panel 2000 EN Control Panel has three outputs on the main
board and 8 outputs on the DX3010 relay module. The Output 1 is used as Siren alarm. During
the alarm duration, the system can reset the alarm by command "reset" . The other outputs
can be programmed to follow up different events.
8.4.1

Output Events Option

0 – No output activate for the events
This output doesn't operate for any events codes. OC outputs are open status. Relay is normal
open status.
1 – System Disarmed
The output operates on below conditions:
1.
2.
The output is reset:
1.
2.
2 – System Armed
The output operates on below conditions:
1.
System operated the arm command and until system is armed. (When system is operating the
arm command, the system will arm after the exit delay time is up.)
Bosch Sicherheitssysteme GmbH
When the Code holder operates the below command:
CODE + [5] + [#]
The system display the above five types of system events.
Other events are not displayed on the keypad.
Each event displays one second and activate the short beep sound on the keypad. The
events are played bace in reverse chronological order.
System disarmed after system reset
System operated the disarm command
When the system is armed
When the output programmed duration is up
System armed after system reset
Installation Manual
Keypad Indication
LED 1-8 light
FAULT Indicator lights
STAY Indicator lights
AWAY Indicator lights
All indicators are extinguished
System Informations 2 | en
F.01U.241.127 | V4 | 2011.12
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax panel 2000 en

Table of Contents