en | System Informations 2
Keypad – Medical Report
A Medical Report is sent to the base station destination when a user presses [7] and [9] at the
same time.Restore Reports are not sent for this event.
System Status – AUX Power Supply Fail Report
A System Fault Report is sent when the AUX Power Supply is fail.
System Status – AUX Power Supply Fail Restore Report
A System Trouble Restore Report is sent when the failed keypad AUX Power Supply is
restored fault is reset.
System Status – AC Fail Report
An AC Fail Report is sent to the base station destination when the AC MAINS supply is
disconnected.
System Status - AC Fail Restore Report
An AC Fail Restore Report is sent when the AC MAINS supply is connected and fault is reset.
System Status – Low Battery Report
A Battery Test Failure Report is sent to the base station destination when a dynamic battery
test detects a low capacity battery or the battery voltage falls below 11.5VDC+ -5%.The
control panel continually monitors the battery voltage. A dynamic battery test is performed
every time the system is armed, every time as set in Location 191 and after the control panel
is powered up.
System Status – Low Battery Restore Report
A Low battery restore report is sent when the Battery comes to normal and fault is reset.
System Status – Access Denied (Code Retry)
An Access Denied Report is sent to the base station destination when the number of incorrect
code attempts equals the number programmed. Restore reports are sent when fault is
reset.The Code Retries feature restricts the number of times an invalid User Code can be
entered in an attempt to operate the system. Programming sets the number of incorrect code
attempts that causes an alarm. When the number of incorrect code attempts equals the
number programmed in this location, the system performs these actions:
8.2.3

Auto Test Report

The system supports to send the test report automatically.The test report can be programmed
as routine and daily timer.
F.01U.241.127 | V4 | 2011.12
Activates the sirens and other alarm output.
Shuts down all keypads for 3 minutes.
Sends an Access Denied Report to the base station destination.
When programmed the address 145-146 as 1-99, it will send the routine test report
based on the assigned hours set in the location. When programmed the address 145-146
as 0, no routine test report.
When programmed the address 147-150 as real time data, the system will send the real
time report at the same time of every day. If the users need the real time report, the date
and time must be set, otherwise, no test report is sent out. If program data is out of the
hour/minute range, the daily timer test report will be disabled.
Installation Manual