Bosch AMAX panel 2000 Installation Manual page 61

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
3.
12- Key switch Toggle
If a zone is programmed as key-switch toggle, it will ignore all other programming items, such
as bypass, forcing arm.If the Zone Tamper function is enabled, the zone will process as zone
tamper.When a zone is programmed for key-switch arming then that zone is the input for a
momentary (toggle mode) keyswitch input. In toggle mode, every time the keyswitch input is
triggered the system will be armed.
Zone trigered: AWAY Arm
Zone normal: No effect
When the system is armed in this mode, the keypad activates two beeps and report sent is by
User Code 17
13- Key switch on/off
If a zone is programmed as key-switch On/Off, it will ignore all other programming items, such
as bypass, forcing arm.If the Zone Tamper function is enabled, the zone will process as a zone
tamper. When a zone is programmed for key-switch arming then that zone is the input for a
On/Off keyswitch input. In On/Off mode, the control will arm when the zone is zone triggered
and disarm when it is normal. This zone allows the system to be armed or disarmed with an
on/off switch wired across the keyswitch zone.
Key-switch On/Off Zone activates no alarm event. Zone trigered: Activate AWAY Arm. Zone
normal: Activate Disarm
Wiring Diagram for Key-switch Zone: short for arm. The momentary time is capable of lasting
Min. 300ms.
Wiring Diagram for Key-switch Zone: short for arm. The momentary time is capable of lasting
Min. 300ms.
When the key-switch operates the Arm/Disarm, the keypad sounds two beeps and report sent
to the system by User Code17.
NOTICE!
As the key-switch operates the arm/disarm successfully, the siren sounds short to indicate it.
Bosch Sicherheitssysteme GmbH
STAY Arm: Same as AWAY Arm performance.
This zone is mainly for prevention of arming (to ensure exit/entry door is locked before
arming the system and no alarm occurs when entering the premise through the entry/
exitdoor)
COM
Zone
COM
Zone
Installation Manual
System Informations 2 | en
F.01U.241.127 | V4 | 2011.12
61