Arming In Stay Mode - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
The AWAY indicator flashes slow, and exit time starts. After exit time, the AWAY indicator is lit.
Please contact your installer to enable/disable this function.
Telephone remote arming
The user dials the control panel number. The control panel answers the call and issues a long
beep. After the long beep, the user must press the [#] key. When the Panel receives the signal
it will confirm the arming of the control panel with a high tone.
Please contact your installer to enable/disable this function.
Arming in AWAY mode with wireless remote control Key
Press and hold the Arming Button until two beeps sound on the remote keypad and the AWAY
indicator flashes slow. Exit time starts. After exit time, the AWAY indicator is lit.
RE012E:2 standard wireless remote control key
1 –Button 1: Arm in AWAY mode
2 –Button 2: Disarm
3 –Button 1 and 2: Press both buttons at the same time to activate Panic alarm
Key switch arming
Users can use a key switch to Arm and Disarm the system. When the Key switch is activated,
the AWAY indicator flashes slow and exit time starts. After exit time, the AWAY indicator is lit.
When the Key switch is deactivated, the system is disarmed and Away indicator is off.
4.1.2

Arming in STAY mode

STAY Mode is used when you need to arm the perimeter and unused areas of the premises to
detect a would-be intruder, while at the same time being able to move freely within an area
that is automatically isolated
There are two methods to arm your system in STAY Mode
To arm the system in STAY mode (method 1)
Enter your code and press [#].
Two beeps sound, the STAY indicator flashes slow and exit time starts. After exit time, the
STAY indicator is lit.
The lights corresponding to all zones programmed as automatically isolated zones (Interior
Instant Zone) begin to flash and continue until the exit time is finished.
To arm the system in STAY mode (method 2)
Press and hold [#] for 3 seconds.
When two beeps sound, release the button.
The STAY indicator flashes slow and exit time starts. After exit time, the STAY indicator is on.
Please contact your installer to enable/disable this function.
Bosch Sicherheitssysteme GmbH