Binary control
[(14) Playback operation by a Level signal input activation]
Contact-activated input P002
Contact-activated input P003
(Activation method)
Close the Playback control input terminal while the Contact-activated input terminal corresponding to the
program number to be played is being closed.
(Operation description)
Even if the P003 is selected by the Contact-activated input terminal during P002 program playback, P003 will
not be played regardless of the priority level, thereby keeping P002 playback as there is no Playback control
input signal for staring P003 playback.
[(15) Recording operation by a Pulse signal input activation]
Contact-activated input 00002
(Activation method)
Close the Recording control input terminal while the Contact-activated input terminal corresponding to the
phrase number to be recorded is being closed.
(Operation description)
Audio source will be recorded to the Phrase No. 00002 when recording starts.
Recording stops when the Stop control input terminal is closed or the Start/Stop key is pressed.
Also, recording stops when the remaining recordable time reaches "0."
Note
You cannot perform any other operation until recording stops once started.
48
Playback control input
Program playback
Recording control input
Stop control input
Phrase recording
P002 selection
P003 selection
P002 playback start
P002 playback
Phrase 00002 selection
Recording start
Phrase 00002 recording
Stop activation