16.2. Operation and Setting at the Time of Emergency Broadcast

• When the emergency broadcast is initiated, the program playback in operation is stopped, allowing the
emergency broadcast to take precedence.
• The EV-700 returns to the Lock mode after the emergency broadcast is stopped.
• Emergency broadcast is disabled while the Maintenance indicator is lighting. (Except when making emergency
playback through the front panel operation)
[Emergency broadcast setting contents list]
Repeat count
Repeat time
Repeat interval
Busy output during interval
Priority level
Emergency playback busy
output destination
R.E.M. busy output
destination (See p. 87.)
Output destination
Program sound volume
AGC
Emergency playback
Setting range
0 to 127 times, infinite
5 to 120 minutes (in
5-minute units), infinite
0 to 50 seconds (in
10-second units), 1 to
99 minutes (in 1-minute
units)
ON/OFF
1
Contact control output
terminals 1 − 8
Line output 1,
Line output 2
0 − 10
ON/OFF
Factory-preset
Setting range
setting
Infinite
0 to 127 times, infinite
5 to 120 minutes (in
Infinite
5-minute units), infinite
0 to 50 seconds (in
10-second units), 1 to
0 second
99 minutes (in 1-minute
units)
ON
1
Contact control
Contact control output
output terminals
terminals 1 − 8
1, 2
Contact control output
terminals 1 − 8
Line output 1,
Line output 1,
Line output 2
Line output 2
10
ON
R.E.M. playback
Factory-preset
setting
Infinite
Infinite
0 second
ON/OFF
ON
1
Contact control
output terminals
1, 2
None
Line output 1,
Line output 2
0 − 10
ON/OFF
ON
1
10
65