12.3.2. Pulse signal input activation and Level signal input activation
Pulse signal input activation: Activates operation when a make signal (Closed time duration: over 50 ms) is
Level signal input activation: Activates operation when a make signal is applied to the terminals, and continues
[Operation by Pulse signal input activation] (When Direct control function is selected)
• Operation of playback start by Pulse signal input activation
Contact-activated input
Unit's playback operation
• Operations of playback start by Pulse signal input activation and Stop activation during playback.
Contact-activated input
Stop control input
Unit's playback operation
Note
When set to Pulse signal input activation, playback is not repeated even if a closed state is kept at the end of
the program playback.
Contact-activated input
Unit's playback operation
When set to Pulse signal input activation, set the closed duration of the make signal to the time duration not
longer than 1 second.
applied to the terminals. Operation stops when it is finished or when a make signal
is applied to the Stop control input.
the operation while the terminals are being closed.
Playback is repeated when a closed state is maintained even if playback is finished.
ON
OFF
Program
ON
OFF
OFF
Program
OFF
Program
ON
ON