ADFM® Flow Meter
Section 1 Introduction
1.2 Initial Inspection
Contact Information
1.3 Technical
Specifications
Table 1-1 Technical Specifications: ADFM Controller
Electronics Unit Enclosures
Operating Temperature
Storage Temperature
Packaging
Box
Canister
Dimensions
Box
Canister
Weight
Box
Canister
Flow
Accuracy
Velocity
Maximum Velocity
Velocity Bin Size
1-2
Upon receipt, inspect the shipping container for any damage. If
the shipping container or packing material shows signs of
damage, it should be retained until the contents have been
inspected for completeness and the system has been checked
both mechanically and electrically. If the contents are incomplete
or damaged, or if the system indicates a failure in some com-
ponent during initial testing, notify Teledyne Isco as soon as pos-
sible, and notify the carrier regarding any damage to the
shipping container and packing material.
Technical assistance for the ADFM flow meter can be obtained
from:
Teledyne Isco
4700 Superior St.
Lincoln NE 68504
Phone: (866) 298-6174 or (402) 464-0231
Fax: (402) 465-3022
E-mail: IscoService@teledyne.com
The following tables provide technical specifications for the
ADFM box and cylindrical electronics controllers, and for the
Pro20 open channel and Hot Tap Insertion velocity sensors.
Physical
Wall or console-mounted box, or cylindrical canister
-15 to 125 °F (-26 to 52 °C)
-65 to 160 °F (-54 to 71 °C)
NEMA 4X (IP66)
NEMA 6P (IP68)
17.5 x 14.8 x 6.7 in. (445 x 375 x 170 mm)
28.5 x 10 in. (724 x 254 mm)
24 lbs (11 kg)
36 lbs (16 kg)
Measurement Performance
2% of reading in typical conditions
±30.0 ft/s (± 9m/s)
2 to 12 inches (50 to 3000 mm) - user selectable