Pro20: Cabling - Teledyne ADFM Pro20 Installation And Operation Manual

Acoustic doppler flow meters
Hide thumbs Also See for ADFM Pro20:
Table of Contents

Advertisement

ADFM® Flow Meter
Section 2 Setup and Installation
Figure 2-26 Sensor alignment with channel wall

2.6.3 Pro20: Cabling

Figure 2-27 Sensor cable direction
2-28
The long side of the sensor must be parallel with the longitudinal
axis of the channel.
Flow
NO
Sites where a large amount of aeration or turbulence will be
present often require the use of a secondary pressure transducer.
In these cases, the mounting of the secondary sensor, including
elevation and orientation, must also be considered.
Be careful to route the cable away from the side of the sensor
where it is attached. Improper cable routing increases the possi-
bility of debris fouling.
NO
Flow
During installation, ensure that the cable connector end is sealed
for protection in case it comes into contact with water.
If a mounting apparatus (such as a ring or rectangular frame) is
used, cables should be fastened to its downstream side. All per-
manent installations require the cables to be secured to the
channel wall and mounting apparatus with rubber-cushioned
stainless steel loop straps at 6" (nominal) intervals.
Flow
YES
YES
Minimum bend
radius 6"
Flow

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adfm hot tap

Table of Contents