Applications With Permanent Silt - Teledyne ADFM Pro20 Installation And Operation Manual

Acoustic doppler flow meters
Hide thumbs Also See for ADFM Pro20:
Table of Contents

Advertisement

Figure 2-36 Installation example
2.6.7 Applications With
Permanent Silt
Cable Conduit
(min. 2" dia.)
Minimum bend
radius 6"
Cable in this area
MUST be secured and protected.
Sensor mounting
plate
For pipes or channels where sediment or debris will be present,
Teledyne Isco offers mounting accessories for elevating the
sensor.
The debris fairing attaches directly to the mounting plate or ring,
and the sensor is mounted in the top of the fairing for a lift of 3
inches. Fairing spacers add 1, 2, and 4 inches each, and may be
combined for additional lift.
The sensor, fairing, and spacer(s) are attached to the mounting
plate with three threaded couplers and mounting screws.
ADFM® Flow Meter
Section 2 Setup and Installation
Align sensor(s) parallel
w/ the channel walls and
flat on the channel bottom.
2-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adfm hot tap

Table of Contents