List of parameters for CONFIGURATION MENU

Ipa
Parameter Name
11000
Control Selector
11002
MasterSlave
11004
Nominal pump speed
11006
Nominal pump press
11008
Full Scale Pres Sens
11010
Pump Direction
11012
Analog Pres Gain
11014
Auto Setup
Control Selector
Master Slave
Nominal pump speed
Nominal pump press
Full Scale Pres Sens
Pump Direction
Note!
Positive or negative is just conventional.
This parameter must be set carefully. A wrong setting of this parameter can lead to pump damaging.
Note!
After you select the pump direction in the application all the speed value in the PID-IMM application are shown with
positive value also if pump direction is negative. Example, if direction is negative and speed is 200rpm what happen?
If you read PID-IMM/MONITOR [12006] Speed Feedback = 200rpm but if you read MONITOR [260] motor speed =-
200rpm (real speed of the motor). If Pump direction is positive both parameters are positive.
Analog Pres Gain
Auto Setup
ADP200 Application PID-IMM
Unit
-
-
rpm
bar
bar
-
-
-
Setting of application control type.
1= SPEED
2= ADP200
Configuration of the drive for multipump. It can be:
0=Master
1=Slave
2=SlaveDivMaste
3=SlaveDivSlave
Gear pump rated speed; used to scale the speed reference signal
Gear pump rated pressure; used to scale the pressure reference signal
Pressure sensor full scale value; used to scale the pressure feedback signal from
pressure transducer.
Gear pump direction of rotation; can be POSITIVE or NEGATIVE according to the
capability of the pump to generate pressure with related direction of rotation.
0=NEGATIVE
1=POSITIVE
Gain applied on pressure feedback signal.
This parameter can be used to adjust tolerance on pressure transducer.
This command will set the drive system parameter in order to be ready for standard
application (0...10 V Analog Input Signals) see paragraph 4.3.
When active the parameter perform the operations and automatically return "OFF"
(in ADP200 Fw1_0_0 PID-IMM 1-x.37.0 the transition from "On" to OFF" value
must be done manually.
0=OFF
1=ON
Starting with version PID IMM V1_x_37_2, the Auto-setup command compiles the
Recipe, i.e., the following default parameters are inserted in menu 29-Recipe:
Type
CONT TYPE
CO_MASTER_SLAVE
FLOAT
FLOAT
FLOAT
PUMP DIRECTION
FLOAT
BOOL
User Manual
Default
Min
ADP200
0
MASTER
-
2400
0.00
4000.00
140
0.00
1000.00
250
0.00
1000.00
NEGATIVE
-
1
0.10
OFF
-
Pag. 41 of 80