Enabling Snmp Agents - Adaptec PCI Ethernet and Fast Ethernet Adapters User Manual

Pci ethernet and fast ethernet adapters
Table of Contents

Advertisement

PCI Ethernet and Fast Ethernet Adapters
Note:
When configuring the primary adapter in
failover mode, provide the index number for the
backup adapter. When configuring the backup
adapter, provide the index number for the primary
board.
9
Press Esc and save the configuration.
10
To configure the backup board, repeat steps 4-9.
11
Confirm that the two boards are installed and configured, then
select PROTOCOLS from the main menu and make sure that
your network protocols are enabled. IPX/SPX is enabled by
default.
12
When your protocols are enabled and configured (TCP/IP
numbering scheme), select Bindings from the main menu.
13
Select INSERT and select the protocol to bind to the network
adapter.
14
Repeat steps 11-13 for the second (Backup) adapter.
15
Highlight the backup adapter and press Tab to disable it. This
insures proper Failover operation and traffic routing.
16
View CONFIGURATION to make sure that the boards are
installed and configured properly.
17
Press Esc and exit the INETCFG utility.
18
At the server console type down and then type restart system to
start the new configuration. Initial configuration of the driver
is complete.

Enabling SNMP Agents

1
Add the following two lines at the end of the
sys:system/autoexec.ncf file.
LOAD CDTDMI
LOAD FAILMIB
The installation and initial configuration of the driver is
complete.
2
Reboot for the configuration to take effect.
4-6
PCI Ethernet and Fast Ethernet Adapters User's Guide
Stock Number: 511472-00, Rev. A
Print Spec Number: 496708-00
Current Date: 5/5/97
Page: 4-6
ECN Date: 5/97

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF