Install Electrical Wiring
This section provides information to install the electric
pre-wiring required for use with the decorative lighting,
or the optional GV60WIFI WiFi Kit.
WARNING
All wiring must be done by a qualified
electrician in accordance with local codes
or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1.
Electrical Requirements
Lighting: 120 VAC, 35 W per bulb (qty 2)
V-Module: 120 VAC, 210 W
GV60WIFI: 6 VDC (from receiver), less than 1 amp
General Requirements
The decorative lighting and optional GV60WIFI module
are powered by the V-module included with the appli-
ance. The V-module includes a three-prong plug to plug
into a grounded receptacle installed within the fi replace
enclosure by a qualifi ed electrician.
The receptacle, housing, and strain relief are supplied
and installed as part of the fi replace.
Notes
• We recommend connecting the electrical box to use
the supplied decorative lighting and the time of fi re-
place installation. It is much easier to wire before wall
fi nish is applied.
3"
[77 mm]
Right side view
34
2-1/16"
[53 mm]
• Wiring within the receptacle enclosure must have a
minimum 90°C temperature rating.
• Wire nuts not included.
WARNING
Electrical connection IS NOT ALLOWED
when adapting appliance for outdoor use.
Installation
1. Disconnect/isolate power from the wiring being run
to the fi replace.
2. Locate the electrical housing. It is behind the front
panel of the fi replace in the bottom right corner.
Inner
Cover
Receptacle
Grounding
Stud
3. Remove the inner cover (2 screws).

Electrical Wiring

Strain
Relief
Outer
Cover