Installation; Installing Electrical Wiring - Valor LX1 Installation Manual

Hide thumbs Also See for LX1:
Table of Contents

Advertisement

Installation

Installing Electrical Wiring

This section provides information to install the electric
wiring required for use with your fi replace's lighting and
other options.
All wiring must be done by a qualifi ed electrician in
accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Electrical Requirements
120 V, 60 Hz, grounded supply, less than 1 amp.
General Requirements
The included V-Module power supply includes a three-
prong grounded plug to plug into a grounded receptacle,
also included with the fi replace. The receptacle needs to
be wired up within the fi replace enclosure by a qualifi ed
electrician.
Installation
1. Locate the electric box at the wall end of the
fi replace.
2. Remove the cover (4 screws).
3. Open the cover and pull out the 3 wires and terminal
blocks attached to the receptacle inside the box.
4. Punch out the cover knockout you want to pass the
supply wiring through.
5. Install strain relief (not supplied) and pass supply
wiring through. Do not tighten strain relief yet.
Electrical Wiring