5.4.2.3 Object 6060h: Modes of Operation (DS402)

This object is used to set the mode, which can be read out by Object 6061h.
Two types of operating mode are used:
manufacturer-specific operating modes.
These modes of operation have been optimized to the functionality of the equipment.
operating modes as per CANopen drive profile DS402
These operating modes are defined in the CANopen drive profile DS402.
After the mode has been changed, the corresponding setpoint must be set once more (for
instance, the homing velocity in the mode homing_setpoint). If the position or jogging mode is
stored, then the Homing mode is set after a RESET of the servo amplifier.
An operating mode only becomes valid when it can be read by Object 6061h.
Risk of death or serious injury for humans working in the machine. The drive could move unex-
pectedly. When the drive is enabled, a mode change is only permissible at zero speed.
Never change the mode while the motor is running!
Set the speed setpoint to 0 before changing over.
Index
Name
Object code
Data type
Category
Access
PDO mapping
Value range
Default value
Supported modes (negative values are manufacturer specific modes):
Value (hex)
Automatic Restart!
6060h
mode of operation
VAR
INTEGER8
mandatory
rw
possible
80h ... 88h, 1, 3, 4, 6, 7
Mode
80
Digital velocity control mode
81
Analogue velocity control mode
82
Digital current control mode
83
Analog current control mode
84
Electronic gearing
85
reserved
86
reserved
87
reserved
88
Motion task mode
1
Profile position mode
3
Profile velocity mode
4
Profile torque mode
6
Homing mode
7
Interpolated position mode
S300-S700 CANopen | 5   CANopen Drive Profile
Kollmorgen | kdn.kollmorgen.com | December 2019
61