Festo CPX Series Manual page 179

Terminal, analogue i/o modules, sub-bases
Hide thumbs Also See for CPX Series:
Table of Contents

Advertisement

5. Analogue input module CPX-4AE-T
Channel parameters: Diagnostic message in the event of wire break or
Function no.
4828 + m * 64 + 7 (channel 0 ... 3)
Description
Sets whether or not a diagnostic message is to be displayed after wire break or
short circuit. The parameter can be set for the individual channels independently
of each other.
Bit
Bit 0/1:
Bit 2/3:
Bit 4/5:
Bit 6/7:
Values
Channel 3
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0
0
Comment
Tab. 5/10: Diagnostic message channel x
Festo P.BE-CPX-AX-EN en 1107f
short circuit channel x
channel 0
channel 1
channel 2
channel 3
Channel 2
Channel 1
0
0
0
0
1
0
1
0
m = module number (0 ... 47)
Channel 0
0
0
0
No diagnostic message
(presetting)
1
0
1
Diagnostic message in the
event of wire break or
short circuit