9.1.2 Circuit diagram twin system from model year 01/10)

9.2 Switch unit (up to model year 12/09)

9.2.1 Switch unit for single system (up to model year 12/09)
Description of the display and control elements
Display elements (LED's)
(for information
Normal mode
for the operator)
(for information for the
Malfunction
fitter, motor protection
switch also for the operator)
Control elements
Manual - 0 - Auto
Alarm Reset
Motor protection switch
9. Control unit
Operation
Level „Alarm"
Level „On"
Level „Off"
Pump
Phase/rotary field
Motor protection switch red
Motor temperature
Running time / Level
Sliding switch
Key
Switch
73
yellow Voltage supply OK
yellow "Alarm" level reached
yellow On" level reached
yellow no function
yellow Pump output activated
red
Permanently lit: Phase failure (has display priority)
Flashing:
Motor protection switch has triggered
red
Flashing:
red
Permanently lit: Running time fault
Flashing:
Choice of operating mode
Reset / alarm signal sensor test
Reset of a level fault display
Reset of excess motor temperature
Triggered when pump has excess current
Rotary field fault
"Temperature A" (TF)
Level fault
saving - priority treatment