9 Interfaces
9.10.4

Absolute encoder (SSI)

Reference ground is EGND (terminal X10 Pin 2)
Number of bits: 13..32
Format: Binary or Gray
Clock frequency SSI-Clock: 100 kHz or 300 kHz (set with command FS)
Maximum voltage range ref. to EGND: 5 V DC