Control Circuit Terminal Functions
The functions available by using the control circuit terminals are shown in Table 2.8. Use the appropriate ter-
minals for the correct purposes.
No.
Type
Se-
quence
input
signals
S10
S11
S12
Analog
input
signals
E(G)
-18
2
Signal Name
S1
Forward Run/Stop Command Forward run when on, stopped when off.
S2
Reverse Run/Stop Command Reverse run when on, stopped when off.
*1
S3
Multi-Function Input 1
*1
S4
Multi-Function Input 2
*1
S5
Multi-Function Input 3
*1
S6
Multi-Function Input 4
*1
S7
Multi-Function Input 5
*1
S8
Multi-Function Input 6
*1
S9
Multi-Function Input 7
*1
Multi-Function Input 8
*1
Multi-Function Input 9
Multi-Function Input 10
SC
Sequence input common
+V
+15 V power output
-V
-15 V power output
Master Speed Frequency
A1
Reference
A2
Multi-Function Analog Input
A3
Multi-Function Analog Input
AC
Analog reference common
Shield wire, optional ground
line connection point
Table 2.8 Control Circuit Terminals
Function
Default: External Fault when on.
Default: Fault Reset when on.
Default: Multi-Speed Reference 1 enabled
when on.
Default: Multi-Speed Reference 2 enabled
when on.
Default: Jog Frequency selected when on.
Default: External Baseblock when on.
Default: Multi-Speed Reference 3 enabled
when on.
Default: Multi-Speed Reference 4 enabled
when on.
Default: Accel/Decel Time selected when on.
Default: Emergency Stop (N.O. contact)
*1
when on.
-
+15 V power supply for analog references
-15 V power supply for analog references
-10 to +10 V/-100 to 100%
0 to +10 V/100%
4 to 20 mA/100%, -10 to +10 V/-100 to
+100%, 0 to +10 V/100%
Default: Added to terminal A1
(H3-09 = 0)
-10 to +10 V/-100 to +100%, 0 to +10 V/
100%
Default: Analog speed 2 (H3-05 = 2)
0 V
-
Signal Level
24 VDC, 8 mA
Photocoupler isolation
+15 V
(Max current: 20 mA)
-15 V
(Max current: 20 mA)
-10 to +10 V, 0 to +10 V
(Input impedance:
20 kΩ)
4 to 20 mA (Input imped-
ance: 250 Ω)
-10 to +10 V, 0 to +10 V
(Input impedance:
20 kΩ)
-10 to +10 V, 0 to +10 V
(Input impedance:
20 kΩ)
-
-