YASKAWA CIMR-ACA4011 Instruction Manual page 159

Varispeed ac, matrix converter for environmentally friendly motor drives
Table of Contents

Advertisement

Name
Parameter
Number
Display
Power frequency
U2-24
*
Power Frequency
Input Power Info
U2-25
*
Power Status
* Applicable for the Varispeed AC with software versions PRG: 1050 or later.
Note: The error trace does not include the following errors: CPF00, 01, 02, 03, and power faults.
U3: Fault History
Name
Parameter
Number
Display
Most recent fault
The error contents of 1st previous
U3-01
fault.
Last Fault
Second most
The error contents of 2nd previ-
recent fault
U3-02
ous fault.
Fault Message 2
Third most recent
The error contents of 3rd previous
fault
U3-03
fault.
Fault Message 3
Fourth/oldest fault The error contents of 4th previous
U3-04
fault.
Fault Message 4
Cumulative opera-
The total operating time when the
tion time at fault
U3-05
1st previous fault occurred.
Elapsed Time 1
Accumulated time
The total operating time when the
of second fault
U3-06
2nd previous fault occurred.
Elapsed Time 2
Accumulated time
The total operating time when the
of third fault
U3-07
3rd previous fault occurred.
Elapsed Time 3
Accumulated time
of fourth/oldest
The total operating time when the
U3-08
fault
4th previous fault occurred.
Elapsed Time 4
* Applicable for the Varispeed AC with software versions PRG: 1050 or later.
Note: The error log does not include the following errors: CPF00, 01, 02, 03, and power faults.
Description
Monitors the input power supply fre-
quency in the MxC.
Information on the input power supply
U2-25=
00000000
bit0: Power detect
0: Not 1: Detect
bit1: Phase Direction
0: For 1: Rev
bit2: Rated Power Frequency
0: 60 Hz 1: 50 Hz
bit3: SRC Detect
0: Not 1: Detect (SRC)
bit4: FDEV Detect
0: Not 1: Detect (FDEV)
bit5: AUV Detect
0: Not 1: Detect (AUV)
bit6: FSTABLED detect
0: Not 1: End (FSTABLE)
bit7: RFINI_FLAG detect
0: Not 1: End (RFINI_FLAG)
Description
No output available
Output Signal
Level during Multi-
Min.
Function Analog
Unit
Output
10 V: 60 Hz
0.1 Hz
(0 V to +10V possible)
No output available
-
Output Signal Level
Min.
during Multi-Function
Unit
Analog Output
-
-
-
-
1 hr
1 hr
1 hr
1 hr
Parameter Tables
Control
Methods
MEMO-
BUS
Open
Flux
Register
V/f
Loop
Vector
Vector
A
A
A
7E9H
A
A
A
7EAH
Control
Methods
MEMO-
BUS
Open
Flux
Register
V/f
Loop
Vector
Vector
A
A
A
90H
A
A
A
91H
A
A
A
92H
A
A
A
93H
A
A
A
94H
A
A
A
95H
A
A
A
96H
A
A
A
97H
63
5-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents