Digital Operator Functions
This section explains the digital operator functions.
Setting Digital Operator Functions
The user can set digital operator-related parameters such as selecting the digital operator display, multi-func-
tion selections, and copy functions.
Related Parameters
Name
Parameter
Number
Display
User Monitor
Selection After
Power-Up
o1-02
Power-On Monitor
Digital Operator
Display Selection
o1-03
Display Scaling
Setting unit for fre-
quency parameters
related to V/f char-
o1-04
acteristics
Display Units
Local/Remote Key
Function Selection
o2-01
Local/Remote Key
STOP Key Func-
tion Selection
o2-02
Oper STOP Key
* The digital operator shows rpm instead of min
Description
Sets the monitor item to be displayed when
the power is turned on.
1: Frequency reference
2: Output frequency
3: Output current
4: The monitor item set for o1-01
Sets the units that will be set and displayed for
the frequency reference and frequency moni-
tor.
0: 0.01 Hz units
1: 0.01% units (Maximum output frequency
is 100%)
2 to 39:
−1 ∗
min
units (Sets the motor poles.)
40 to 39999:
User desired display
Set the desired values for setting and dis-
play for the max. output frequency.
Set 4-digit number
excluding the decimal
point.
Set the number of digits
below the decimal point
to display.
Example: When the max. output frequency
value is 200.0, set 12000.
Set the setting unit for frequency reference-
related parameters.
0: Hz
−1 ∗
1: min
Determines if the digital operator LOCAL/
REMOTE key is functional.
0: Disabled.
1: Enabled.
Determines if the STOP key on the digital
operator will stop the MxC when MxC is
operating from external terminals or serial
communication.
0: Disabled.
1: Enabled.
-1
.
Digital Operator Functions
Control Methods
Change
Setting
Default
during
Range
V/f
Run
1 to 4
1
Yes
A
0 to
0
No
A
39999
0 or 1
0
No
No
0 or 1
1
No
A
0 or 1
1
No
A
Open
Flux
Loop
Vector
Vector
A
A
A
A
No
A
A
A
A
A
125