Acceleration and Deceleration Characteristics
This section explains the acceleration and deceleration characteristics of the MxC.
Setting Acceleration and Deceleration Times
The "acceleration time" refers to the time it takes for the output frequency to climb from 0% to 100%, while
"deceleration time" refers the time taken for the output frequency drop down to 0%. The default acceleration
time is C1-01, and the default of the deceleration time is C1-02.
Related Parameters
Name
Parameter
Number
Display
Acceleration Time
1
C1-01
Accel Time 1
Deceleration Time
1
C1-02
Decel Time 1
Acceleration Time
2
C1-03
Accel Time 2
Deceleration Time
2
C1-04
Decel Time 2
Acceleration Time
3
C1-05
Accel Time 3
Deceleration Time
3
C1-06
Decel Time 3
Acceleration Time
4
C1-07
Accel Time 4
Deceleration Time
4
C1-08
Decel Time 4
Accel/Decel Time
Setting Units
C1-10
Acc/Dec Units
Accel/Decel
Switch Frequency
C1-11
Acc/Dec SW Freq
Description
Sets the time to accelerate from zero to maxi-
mum frequency.
Sets the time to decelerate from maximum
frequency to zero.
Sets the time to accelerate from zero to maxi-
mum frequency when selected via a multi-
function input.
Sets the time to decelerate from maximum
frequency to zero when selected via a multi-
function input.
Sets the time to accelerate from zero to maxi-
mum frequency when selected via a multi-
function input.
Sets the time to decelerate from maximum
frequency to zero when selected via a multi-
function input.
Sets the time to accelerate from zero to maxi-
mum frequency when selected via a multi-
function input.
Sets the time to decelerate from maximum
frequency to zero when selected via a multi-
function input.
Sets the setting resolution of C1-01 to C1-09.
0: 0.01 s (0.00 to 600.00 s)
1: 0.1 s (0.0 to 6000.0 s)
Sets the frequency for automatic switching of
accel/decel times.
Fout < C1-11: Accel/Decel Time 4
Fout≥C1-11: Accel/Decel Time 1
Multi-function inputs "Multi-Acc/Dec 1" and
"Multi-Acc/Dec 2" have priority over C1-11.
Note: With Multi-Function Input, Accel/
Decel Time 1 and 2 will take prece-
dence.
Acceleration and Deceleration Characteristics
Control Methods
Change
Setting
Default
during
Range
Run
Yes
Yes
Yes
Yes
0.0 to
10.0 s
*
6000.0
No
No
No
No
0 or 1
1
No
0.0 to
0.0 Hz
No
120.0
Open
Flux
V/f
Loop
Vector
Vector
Q
Q
Q
Q
Q
Q
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
17
6-