YASKAWA CIMR-ACA4011 Instruction Manual page 384

Varispeed ac, matrix converter for environmentally friendly motor drives
Table of Contents

Advertisement

No.
Name
L8-12
Ambient Temperature Setting
OL2 Characteristic Selection at
L8-15
Low Speeds
L8-42
Factory Adjustment 1
n1-01
Hunting Prevention Selection
n1-02
Hunting Prevention Gain Setting
n1-03
Hunting Prevention Time Constant
Speed Feedback Detection Con-
n2-01
trol (AFR) Gain
Speed Feedback Detection Con-
n2-02
trol (AFR) Time Constant
Speed Feedback Detection Con-
n2-03
trol (AFR) Time Constant 2
n5-01
Feed Forward Control Selection
n5-02
Motor Acceleration Time
n5-03
Feed Forward Control Ratio Gain
o1-01
User Monitor Selection
User Monitor Selection After
o1-02
Power-Up
o1-03
Digital Operator Display Selection
Setting unit for frequency parame-
o1-04
ters related to V/f characteristics
o1-05
LCD Brightness Adjustment
Local/Remote Key Function Selec-
o2-01
tion
o2-02
STOP Key Function Selection
o2-03
User Parameter Default Value
o2-04
MxC/kVA Selection
Frequency Reference Setting
o2-05
Method Selection
* 1. The default will change when the control method is changed. The Open Loop Vector defaults are given.
* 2. The defaults depend on the MxC capacity. The values for a 200 V class MxC of 5.5 kW are given.
* 3. These are values for a 200 V class MxC. Values for a 400 V class MxC are double.
* 4. E1-11 and E1-12 are disregarded when set to 0.0.
* 5. E1-13 is set to the same value as E1-05 by Auto-Tuning.
* 6. The defaults in the parentheses are for 3-wire sequence.
* 7. Applicable for the Varispeed AC with software versions PRG: 1050 or later.
* 8. Applicable for the Varispeed AC with software versions PRG: 1052 or later.
Table 10.2 Parameters (Continued)
Table 10.2 Parameters (Continued)
Set-
Default
No.
ting
Operation Selection when Digital
45
o2-06
Operator is Disconnected
Cumulative Operation Time Set-
1
o2-07
ting
Cumulative Operation Time Selec-
2
o2-08
tion
Initialization Specification Selec-
1
o2-09
tion
1.00
o2-10
Fan operation time setting
Fault Trace/Fault History Clear
10
o2-12
Function
1.00
o2-14
kWh User Monitor Initialization
*7
100
Capacitor maintenance setting
o2-18
750
o3-01
Copy Function Selection
0
o3-02
Copy Allowed Selection
*3
T1-00
Motor Selection 1/2
0.168
1.0
T1-01
Auto-Tuning Mode Selection
6
T1-02
Motor Rated Power
1
T1-03
Motor Rated Voltage
0
T1-04
Motor Rated Current
0
T1-05
Motor Base Frequency
3
T1-06
Number of Motor Poles
1
T1-07
Motor Base Speed
1
T1-08
Number of PG Pulses
0
T1-09
Motor No-Load current
*2
T1-10
Motor Rated Slip
5
0
Parameters
Name
Default
0
0
0
0
0
0
0
0
0
0
1
0
*2
5.50
*3
200.0
*2
19.60
60.0
4
1750
600
5.10
1.50
Set-
ting
10
23
10-