YASKAWA CIMR-ACA4011 Instruction Manual page 134

Varispeed ac, matrix converter for environmentally friendly motor drives
Table of Contents

Advertisement

Set
Value
E
F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
*
2F
30
31
32
33
36
37
* Applicable for the Varispeed AC with software versions PRG:1050 or later.
-38
5
Fault (ON: Digital operator communications error or fault other than CPF00 and
CPF01 has occurred).
Not used (Set when the terminals are not used).
Minor fault (ON: Alarm displayed)
Fault Reset Command active
Timer function output
Frequency agree 2 (L4-04 used)
Desired frequency agree 2 (ON: Output frequency = L4-03, L4-04 used, and during
frequency agree)
Frequency detection 3 (ON: Output frequency ≤ -L4-03, L4-04 used)
Frequency detection 4 (ON: Output frequency ≥ -L4-03, L4-04 used)
Overtorque/undertorque detection 1 NC (NC Contact: Torque detection at off)
Overtorque/undertorque detection 2 NO (NO Contact: Torque detection at on)
Overtorque/undertorque detection 2 NC (NC Contact: Torque detection at off)
During reverse run (ON: During reverse run)
During baseblock 2 (OFF: During baseblock)
Motor selection (Motor 2 selected)
During regeneration (ON: During regeneration)
Restart enabled (ON: Restart enabled.)
Motor overload (OL1, including OH3) pre-alarm (ON: 90% or more of the detection
level)
MxC overheat (OH) pre-alarm (ON: Temperature exceeds L8-02 setting)
Maintenance Time
ON: The operation time of either the capacitors on the PCB board or the cooling fan
have reached the specified maintenance time.
During torque limit (current limit) (ON: During torque limit)
During speed limit (ON: During speed limit)
Speed control circuit operating for torque control (except when stopped).
The external torque reference will be limited if torque control is selected (internal
torque reference < external torque reference).
Output when the motor is rotating at the speed limit.
Zero-Servo Complete (ON: Zero-servo function completed)
Frequency (FOUT) detection 5 (ON: Output frequency is equal to or greater than the
set value of +L4-01 or equal to or less than the set value of −L4-01 and L4-02 is used,
off during base blocked)
During Run 2 (ON: Frequency output, off: Baseblock, DC Injection Braking, initial
excitation, operation stop)
Function
Control
Methods
Page
Open
Flux
V/f
Loop
Vector
Vector
Yes
Yes
Yes
-
-
-
-
-
Yes
Yes
Yes
-
Yes
Yes
Yes
-
Yes
Yes
Yes
6-93
Yes
Yes
Yes
6-45
Yes
Yes
Yes
6-45
Yes
Yes
Yes
6-45
Yes
Yes
Yes
6-45
Yes
Yes
Yes
6-49
Yes
Yes
Yes
6-49
Yes
Yes
Yes
6-49
Yes
Yes
Yes
-
Yes
Yes
Yes
-
Yes
Yes
Yes
-
No
No
Yes
-
Yes
Yes
Yes
6-65
6-51
Yes
Yes
Yes
6-78
Yes
Yes
Yes
6-78
Yes
Yes
Yes
6-155
No
Yes
Yes
-
No
No
Yes
6-78
No
No
Yes
6-109
6-78
No
No
Yes
6-123
Yes
Yes
Yes
6-44
Yes
Yes
Yes
6-77

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents