Common Specifications - YASKAWA CIMR-ACA4011 Instruction Manual

Varispeed ac, matrix converter for environmentally friendly motor drives
Table of Contents

Advertisement

Common Specifications

The following specifications apply to MxCs in both 200 V and 400 V classes.
Voltage Class (V)
Model: CIMR-ACAA
Maximum motor capacity (kW)
*2
*3
Rated input current
A
Output capacity (kVA)
Rated output current
Rated
*4
(A)
output
Max output voltage
Max output frequency
Rated voltage and rated
frequency
Allowable voltage
fluctuation
Allowable frequency
Power
fluctuation
Allowable power
voltage imbalance
between phases
Input power factor
Control method
Torque characteristics
Speed control range
Speed control
*6
accuracy
Speed control response
Torque limits
Torque accuracy
Frequency control range
Frequency accuracy
(temperature
characteristics)
Frequency setting
resolution
Output frequency
resolution
Overload capacity and
*7
maximum current
Acceleration/
Deceleration time
Braking torque
Table 9.3 Common Specifications
200
25P5
2011
2022
5.5
11
22
26
47
91
9
17
33
27
49
96
Ratio of input voltage (Input voltage × 0.95)
Applicable for 120 Hz depending on parameter settings.
3-phase: 200 V, 208 V, and 220 V, 50
Hz or 60 Hz
± 3%, fluctuation ratio: 1 Hz/100 ms or less
0.95 or more (When the rated load is applied.)
Sine wave pulse-width modulation (PWM)
Use parameter settings to select from three methods: Flux Vector Control, Open Loop Vec-
150%/0 Hz with Flux Vector Control
1:1000 with Flux Vector Control
± 0.2% with Open Loop Vector Control at -10°C to +40°C,
± 0.05% with Flux Vector Control at 25°C ± 10°C
30 Hz with Flux Vector Control
For vector control only. Use parameter settings to change 4 quadrant control.
± 10% (Flux vector control: 25 °C ±10 °C with a vector motor,
carrier frequency of 4kHz)
Digital references: ± 0.01% (-10 °C to +40 °C),
Analog references: ± 0.1% (25 °C ±10 °C)
Analog references: 0.03 Hz/ 60 Hz (11 bit signed)
150% of rated output current per one minute (for carrier frequency of 4 kHz).
Select from four combinations of independent acceleration and deceleration settings.
Same overload capacity for motoring and regeneration
Standard MxC Specifications
2045
45P5
4011
45
5.5
11
174
14
26
63
10
19
183
15
27
3-phase: 380 V, 400 V, 415 V, 440 V, 460 V, and
480 V, 50 Hz or 60 Hz
+10% to -15%
Within 2%
tor Control, or V/f Control.
*5
*5
*5
0.01 Hz to 120 Hz
Digital references: 0.01 Hz
0.001 Hz
0.00 s to 6000.0 s
400
*1
4022
4045
4075
22
45
75
49
92
157
36
67
114
52
97
165
*5
*5
*5
3
9-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading