Commissioning
8.3.6

DMX Application Example

8.3.6.1

Operation with Deactivated Continuous Send

In this mode, the I/O module only transmits the data for a limited number of DMX
channels according to the set size of the process image (see table "Process data in
the DMX operating mode without continuous send"). Higher refresh rates are then
possible.

Table 39: Process data in the DMX operating mode without transfer optimization

Process
image
length
8 bytes
24 bytes D6
48 bytes D22 Data byte 22
*)
Not in use. In this mode, no data is received.
The transmission method is described in the chapter "Transmission of the
Character String 'Hello World!'"
8.3.6.2

Operation with Activated Continuous Send

In this mode, the output buffer filled with the DMX start byte (always 0) and then
with data for DMX channel 1 to 254.
The transmission method is described in the chapter "Continuous Send".
Observe settings!
To ensure continuous transmission, the "Continuous Send" setting must be
activated!
Input data
S0
Status byte 0
S1
Status byte 1
*)
D0
Data byte 0
*)
D1
Data byte 1
*)
D2
Data byte 2
...
*)
D5
Data byte 5
*)
Data byte 6
...
*)
D21 Data byte 21
*)
...
*)
D45 Data byte 45
750-652 Serial Interface RS-232 / RS-485
Output data
C0
Control byte 0
C1
Control byte 1
D0
Data byte 0
D1
Data byte 1 (DMX channel 1)
D2
Data byte 2 (DMX channel 2)
...
D5
Data byte 5 (DMX channel 5)
D6
Data byte 6 (DMX channel 6)
...
D21 Data byte 21 (DMX channel 21)
D22 Data byte 22 (DMX channel 22)
...
D45 Data byte 45 (DMX channel 45)
WAGO-I/O-SYSTEM 750
DMX start byte (always 0)
Manual
1.2.0