Use in Hazardous Environments
Pos : 86.13 /Alle Serien (Allgemeine M odul e)/Ei ns atz i n Ex-Bereic hen/Errichtungsbes timmungen @ 3\mod_1232453624234_21.doc x @ 26370 @ 2 @ 1
10.2

Installation Regulations

Pos : 86.14 /Alle Serien (Allgemeine M odul e)/Ei ns atz i n Ex-Bereic hen/Errichtungsbes timmungen Ei nleitung @ 3\mod_1232453837234_21.doc x @ 26374 @ @ 1
In the Federal Republic of Germany, various national regulations for the
installation in explosive areas must be taken into consideration. The basis for this
forms the working reliability regulation, which is the national conversion of the
European guideline 99/92/E6. They are complemented by the installation
regulation EN 60079-14. The following are excerpts from additional VDE
regulations:

Table 45: VDE installation regulations in Germany

DIN VDE 0100 Installation in power plants with rated voltages up to 1000 V
DIN VDE 0101 Installation in power plants with rated voltages above 1 kV
DIN VDE 0800 Installation and operation in telecommunication plants including
DIN VDE 0185 lightning protection systems
The USA and Canada have their own regulations. The following are excerpts
from these regulations:

Table 46: Installation regulations in USA and Canada

NFPA 70
ANSI/ISA-RP 12.6-1987 Recommended Practice
C22.1
Pos : 86.15 /D okumentati on allgemei n/Gli ederungsel emente/------Leerz eile------ @ 3\mod_1224662755687_0.doc x @ 24460 @ @ 1
Pos : 86.16 /D okumentati on allgemei n/Gli ederungsel emente/------Leerz eile------ @ 3\mod_1224662755687_0.doc x @ 24460 @ @ 1
Pos : 86.17 /D okumentati on allgemei n/Gli ederungsel emente/------Leerz eile------ @ 3\mod_1224662755687_0.doc x @ 24460 @ @ 1
Pos : 86.18 /Serie 750 ( WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Ac htung: Errichtungsbes timmungen Serie 750 beachten @ 3\mod_1224158893890_21.doc x @ 24191 @ @ 1
Notice the following points
When using the WAGO-I/O SYSTEM 750 (electrical operation) with Ex
approval, the following points are mandatory:
Pos : 86.19 /D okumentati on allgemei n/Gli ederungsel emente/---Seitenwec hs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
information processing equipment
National Electrical Code Art. 500 Hazardous Locations
Canadian Electrical Code
WAGO-I/O-SYSTEM 750
750-652 Serial Interface RS-232 / RS-485
Manual