Process Image

Pos : 64 /D okumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
Pos : 65 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Pr oz ess abbild - Übersc hrift 1 @ 4\mod_1240983067828_21.doc x @ 31942 @ 1 @ 1
4
Process Image
Pos : 66 /Serie 750 ( WAGO-I/O-SYST EM)/Proz ess abbild Kl emmenbus /Hinweis: Prozes sabbildmapping abhängig von FBK/PFC, mit Status-/C ontroll byte @ 4\mod_1242621308640_21.doc x @ 33290 @ @ 1
Mapping of process data in the process image of fieldbus systems
The representation of the process data of some I/O modules or their variations in
the process image depends on the fieldbus coupler/controller used. Please take
this information as well as the particular design of the respective control/status
bytes from the section "Fieldbus Specific Design of the Process Data" included in
the description concerning the process image of the corresponding
coupler/controller.
Pos : 67 /Serie 750 ( WAGO-I/O-SYST EM)/Proz ess abbild Kl emmenbus /Sonder klemmen/Pr ozessabbild 750- 0652_D atenaustausch @ 13\mod_1354192851052_21.doc x @ 107090 @ 22 @ 1
4.1

Operating Modes for Serial Transmission

The data to be sent and received will be stored in up to 46 input and output bytes
(D0 ... D45). Data flow is controlled with control and status bytes C0 and S0 or
C1 and S1. The input bytes form the memory area for up to 46 characters, which
were received by the interface. The characters to be transmitted are sent via the
output bytes.

Table 14: Process data for serial transmission

Process
image
length
8 bytes
24 bytes D6
48 bytes D22 Data byte 22
The structure of the control and status bytes is described in the tables below.
Input data
S0
Status byte 0
S1
Status byte 1
D0
Data byte 0
D1
Data byte 1
D2
Data byte 2
...
D5
Data byte 5
Data byte 6
...
D21 Data byte 21
...
D45 Data byte 45
WAGO-I/O-SYSTEM 750
750-652 Serial Interface RS-232 / RS-485
Output data
C0
Control byte 0
C1
Control byte 1
D0
Data byte 0
D1
Data byte 1
D2
Data byte 2
...
D5
Data byte 5
D6
Data byte 6
...
D21 Data byte 21
D22 Data byte 22
...
D45 Data byte 45
Manual