1-1. Operating Environment

Operating guaranteed temperature :
Performance guaranteed temperature : +10 dC to +35 dC
Operating humidity :
Storage temperature :
Mass
MKS-8010A :
Main panel (4ME):
(3ME):
(2ME):
Prohibited locations for installation
. Areas where the unit will be exposed do direct sunlight
or any other strong lights.
. Dusty areas
. Areas subject to vibration.
. Areas with strong electric or magnetic fields.
. Areas near heat sources.
. Areas where is subject to electrical noise.
. Areas subject to static electricity.
Ventilation
The inside of the MKS-8010A is cooled by a fan (side on
the rear).
The power supply can be damaged if the exhaust vent (side
on the rear) and air intake (front panel) are blocked or the
fan is stopped.
For the MKS-8010A, leave a blank space of more than 10
cm in the front and back sides, and more than 5 cm in the
right and left sides.

1-2. Power Supply

1. Power specifications
A switching regulator is used for the power supply of
MKS-8010A. A voltage within the range of 100 V to 240
V can be used without changing the supply voltage.
Power requirements: AC 100 to 240 V ± 10 %
Power frequency:
50/60 Hz
Current consumption: MKS-8010A: Maximum 3.0 A
CCP-8000 IM
Section 1

Installation

n
As the inrush current flows at turn-on, the capacity of the
AC power source must be commensurate with this load.
+5 dC to +40 dC
If the capacity of the AC power is not adequately large, the
AC power source breaker will operate or the unit will
10 % to 90 %
abnormally operate.
_20 dC to +60 dC
Inrush current
Approx. 11 kg
MKS-8010A: Maximum 14 A (at 100 V)/64 A (at 240 V)
Approx. 42 kg
Approx. 24 kg
2. Recommended power cord
Approx. 20 kg
This unit does not come with a power cord.
To get a power cord, please contact your local Sony Sales
Office/Service Center.
w
. Use the approved Power Cord (3-core mains lead)/
Appliance Connector/Plug with earthing-contacts that
conforms to the safety regulations of each country if
applicable.
. Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Volt-
age, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please contact your local Sony
Sales Office/Service Center.
w
. Never use an injured power cord.
. Plugging the power cord in the AC inlet, push as far as it
will go.
For customers in the U.S.A. and Canada
1 Power cord, 125 V 10 A (2.4 m) : ! 1-551-812-31
1
For customers in the all European countries
1 Power cord, 250 V 10 A (2.5 m) : ! 1-782-929-12
1
AC inlet
AC inlet