3-1-3. Main Panel/AUX Panel
LEDs and other indicators do not light.
Flow 3
LEDs and other indicators do not light.
Is the POWER switch of the
MKS-8010A turned ON?
YES
In case of
main panel
Is the connection cable connected
correctly? (Is the connector (SCU) of
the MKS-8011A connected to the
connector (MENU PANEL) of the
MKS-8010A?)
In case of
AUX panel
Is the connection cable connected
correctly? (Is the connector (SCU) of
the AUX panel connected to the
connector (EXT PANEL 1 to 3) of
the MKS-8010A?)
YES
Is the CTRL LAN cable connected
to the MKS-8010A (CTRL)?
YES
The Main Panel or AUX panel or the
MKS-8010A is probably defective.
3-2. Periodic Inspection and Maintenance
3-2-1. Periodic Inspection
The following parts require periodic maintenance.
Refer to the period indicated in the following list for maintenance.
Part
Location
Fan
Side on the rear of the MKS-8010A
Track ball
MKS-8031ATB
Filter
Front panel on the MKS-8010A
Backup capacitor
The MPU-302B board (BT1301) in the MKS-8010A
3-2
NO
Set it to ON.
NO
Connect the D-sub
50-pin cable.
NO
Connect the LAN
cable.
Maintenance
Suggested period
Cleaning
Once in a month
Cleaning
Once in a month
Cleaning
Once in two months
Replacement
Once in five years
CCP-8000 IM