10.6 Error messages

Any errors that occur are shown in coded form by an error number in the
ERRCODE2
shows additional information coded with "ixx" for faults with an asterix "*" in the table below. The
servo amplifier reaction depends on the fault and on the setting of parameter
hardware reset of the servo amplifier or depending on the fault (see ERRCODE) by ASCII command
Number Designation
E or P
Status messages
. . .
Status message
-
Status message
- S -
STO-Enable
CCC
Memory Card
F01
Heat Sink Temperature
F02
Overvoltage
F03
Following Error
F04*
Feedback
F05
Undervoltage
F06
Motor Temperature
F07*
Internal Voltages
F08
Overspeed
F09
EEPROM
F10
Reserved
F11
Motor Brake
F12
Motor Phase
F13
Ambient Temperature
F14*
Output Stage
F15
I²t max.
F16
Mains BTB/RTO
F17
A/D Converter
F18*
Brake Circuit
F19
Phase error
F20*
Slot Error
F21
Handling Error
F22
Reserved
F23
CAN Bus Off
F24
Warning
F25*
Commutation Error
F26
Limit Switch
F27
STO
F28
Fieldbus Error
F29*
Fieldbus Error
F30
Emergency Timeout
F31
Safety Supervision
F32*
System Error
Explanation (ASCII Reference ERRCODE)
Status messages, no error (➜ # 121)
Updating the startup configuration
Programming mode
STO-Enable input is 0V (with disabled drive only)
Access problems memory card
Heat sink temperature too high limit is set by manufacturer to 80°
Overvoltage in DC bus link limit depends on the electrical supply voltage
Message from the position controller
Cable break, short-circuit, short to ground
Undervoltage in DC bus link, limit is set by manufacturer to 100V
Motor temperature too high or temp. sensor defect
Internal amplifier supply voltages are out of tolerance
Motor over-revs, speed is too high
Checksum error
Reserved
Motor cable break, short-circuit, short to ground
Motor phase missing (cable break or similar)
Ambient temperature too high
Fault in the power output stage or wrong motor cable or bad cable shield-
ing
I²t maximum value exceeded
2 or 3 phases missing in the mains supply feed
Error in the analog-digital conversion
Brake circuit faulty or incorrect setting
Mains phase missed
Slot error, depends on the type of expansion card, see
erence, ERRCODE*
Handling error on the expansion card
Reserved
Severe CAN bus communication error
Warning is displayed as fault
Commutation error
Hardware limit switch error on homing move
Operational error with STO, input for STO-Enable and ENABLE have
been set at the same time
Fieldbus error, see
ASCII object reference, ERRCODE*
Communication disturbed, see
Timeout emergency stop
Safety card error. Error code follows:
oXX=error number, iYY=error subindex
System software not responding correctly
Kollmorgen | kdn.kollmorgen.com | July 2019
S748-772 Instructions Manual | 10   Setup
LED-Display
on the front panel.
ACTFAULT
. Faults can be reset by
ASCII object ref-
ASCII object reference, ERRCODE*
CLRFAULT
123

Hide quick links:

Advertisement

Table of Contents
loading