Wiring Supply Voltage 24 V For Digital Outputs - Kollmorgen S700 Series Instruction Manual

Digital servo amplifier sto dual channel
Hide thumbs Also See for S700 Series:
Table of Contents

Advertisement

S748-772 Instructions Manual | 11   Expansions

11.3.4.3 Wiring supply voltage 24 V for digital outputs

Input X4/5 "STO2-Enable" must be connected to +24V DC and must not be used as addi-
tional STO input!
11.3.4.4 Safe inputs and outputs S2-2
Inputs X30/1 SS1_Activate and X30/20 Reset must always be connected. Only tested out-
puts from a safety control system may be connected to all inputs on X30.
X30
SS1 Activate
I0
I1
I2
STO Acknowledge
O0
O1
O2
O3
24V Supply
n.c.
I3
I4
I5
I6
Ready
n.c.
n.c.
n.c.
Reset
0V Supply
0V Supply
154
Kollmorgen | kdn.kollmorgen.com | July 2019
Pin
I/O Description
1
I
Activates function SS1
2
I
Programmable, activate safety function X
3
I
Programmable, activate safety function X
4
I
Programmable, activate safety function X
5
O
Status: STO activated
6
O
Programmable, status: safety function X activated
7
O
Programmable, status: safety function X activated
8
O
Programmable, status: safety function X activated
9
O
Programmable, status: safety function X activated
10
-
24V supply of digital outputs
11
-
n.c.
12
I
Programmable, activate safety function X
13
I
Programmable, activate safety function X
14
I
Programmable, activate safety function X
15
I
Programmable, activate safety function X
16
O
Message "Safety card is ready to operate"
17
O
n.c.
18
O
n.c.
19
O
n.c.
20
I
Input for Reset
21
-
0V supply of digital outputs
22
-
0V supply of digital outputs
Input STO1-Enable [X4/7] must
not be connected.

Hide quick links:

Advertisement

Table of Contents
loading