9
Connecting to a PC –
Sensor Studio
≤he
graphical user interface for the operation, configuration and diagnosis of sensors with IO-Link configuration
interface (IO-Link devices), independent of the selected process interface.
Each IO-Link device is described by a corresponding IO Device Description (IODD file). After importing the
IODD file into the configuration software, the IO-Link device connected to the IO-Link ≥SB master can be
operated, configured and checked – conveniently and in multiple languages. An IO-Link device that is not
connected to the PC can be configured offline.
Configurations can be saved and reopened as projects for transferring back to the IO-Link device at a later
time.
Only use the
Leuze electronic.
Sensor Studio
≤he
lish, French, Italian and Spanish.
≤he FD≤ frame application of the
be supported in the IO-Link device D≤M (Device ≤ype Manager).
Sensor Studio
≤he
• You make the individual configuration settings for the sensor in the Device ≤ype Manager (D≤M).
• ≤he individual D≤M configurations of a project can be called up via the frame application of the Field
Device ≤ool (FD≤).
• Communication D≤M: IO-Link ≥SB master
• Device D≤M: I/O-Link Device/IODD for ODS 10
NO≤ICE
Configuration changes only via the control!
Always perform the configuration for process mode via the control and, if applicable, the interface.
In process mode, only the configuration conveyed via the control is active. ≤he configuration changes
Sensor Studio
made via
control.
Procedure for the installation of the software and hardware:
Install the
Sensor Studio
Install the driver for the IO-Link ≥SB master on the PC.
Connect the IO-Link ≥SB master to the PC.
Connect the OSD 10 (IO-Link device) to the IO-Link ≥SB master.
Install IO-Link device D≤M with IODD file for ODS 10 in the
9.1
System requirements
Sensor Studio
≤o use the
Leuze electronic
Sensor Studio
configuration software – in combination with an IO-Link ≥SB master – provides a
Sensor Studio
configuration software is offered in the following languages: German, Eng-
Sensor Studio
configuration software is designed according to the FD≤/D≤M concept:
are only active in process mode if they were previously transmitted 1:1 to the
configuration software on the PC.
configuration software, you need a PC or laptop with the following specifications:
configuration software for products manufactured by
supports all languages; all languages may not
Sensor Studio
ODS 10
Connecting to a PC – Sensor Studio