7.3
Setting measure mode
Set the measure mode using the OLED display and the keyboard (Application menu item; see
chapter 3.4.5 "Application menu") or using the
• Standard
Standard setting
• Precision (factory setting)
≤wice as accurate as the standard setting
• Speed
One third as accurate as the standard setting, approx. six times faster
In the table, you will find an overview of how the choice of measure mode affects the individual parameters
of the measurement function.
≤able 7.3:
Measure mode
Standard
Precision
Speed
7.4
Reset to factory settings
Configuration is performed using the OLED display and the keyboard (see chapter 3.4) or using the
Sensor Studio
configuration software (see chapter 9).
Leuze electronic
Measure mode and measurement function parameter
Accuracy
+
+ +
-
Commissioning – sensors with analog interface
Sensor Studio
configuration software (see chapter 9).
Measurement time
20 ms
50 ms
3.5 ms
ODS 10
Measurement value
update
+
- -
+ +