Analog Output Menu - Leuze electronic ODS 10 Manual

Laser distance sensor
Hide thumbs Also See for ODS 10:
Table of Contents

Advertisement

Level 1
Output Q2
3.4.4

Analog Output menu

≤he characteristic output curve of the analog switching output on pin 2 is set in the Analog Output menu.
≤he Analog Output menu is only available for sensors with analog switching output.
Level 1
Analog
Output
Spreading the characteristic output curve
You can spread the characteristic output curve of the analog switching output according to your require-
ments.
 Select the current or voltage range of the analog switching output.
 Set the distance measurement value that corresponds to the lower limit of the measurement range
(4 mA, 1 V, 0 V).
 Set the distance measurement value that corresponds to the upper limit of the measurement range
(20 mA, 10 V).
It is also possible to invert the working range of the analog switching output, i.e., the lower limit of the
measurement range is set to a larger value than upper limit. ≤his creates a descending characteristic
output curve.
Leuze electronic
Level 2
Level 3
Q2 ≥pper Sw. Pt.
Q2 Lower Sw. Pt.
Notice: For the limit values of the measurement range for your sensor, see chapter 13
"≤echnical data".
Q2 Hysteresis
Q2 Light/Dark
Level 2
Level 3
Position Max. Val.
Position Min. Val.
Notice: For the limit values of the measurement range for your sensor, see chapter 13
"≤echnical data".
Analog Range
4 - 20 mA
1 - 10 V
0 - 10 V
Description
≥pper switching point
Lower switching point
Hysteresis
Behavior of the switching output
if an object is within the taught/
configured switching distance.
• Light switching; switching
output active (high)
• Dark switching; switching
output not active (low)
Description
Distance measurement value for
maximum voltage / maximum
current
Distance measurement value for
minimum voltage / minimum cur-
rent
Current/voltage range of the ana-
log switching output
ODS 10
Device description
Default
ODS10L1.8...:
4000 mm
ODS10L1-25.8...:
12500 mm
50 mm
30 mm
Light
Default
≥pper limit of the
measurement
range
50 mm
X
15

Advertisement

Table of Contents
loading

Table of Contents