Roubleshooting; What To Do In Case Of Failure; Led Indicators; Indicators In The Display - Leuze electronic ODS 10 Manual

Laser distance sensor
Hide thumbs Also See for ODS 10:
Table of Contents

Advertisement

10

≤roubleshooting

10.1

What to do in case of failure?

After switching on the sensor, display elements (see chapter 3.3) assist in checking the proper function
and troubleshooting.
In case of error, you can determine the error from the LEDs and the indicators on the display. With the
error message you can determine the cause of the error and initiate measures to rectify it.
 Switch off the system and leave it switched off.
 Analyze the cause of the error using the operation indicators, the error messages and with the help of
Sensor Studio
the
NO≤ICE
Contact Leuze electronic subsidiary/customer service.
 If you are unable to rectify a fault, contact the Leuze electronic branch responsible for you or call the
Leuze electronic customer service (see chapter 12 "Service and support").
10.2

LED indicators

You can use the LED indicators to ascertain general causes of errors; see chapter 3.3.1 "LED indicators".
≤able 10.1:
Error display
Orange
Red
Off
≤able 10.2:
Error display
Off
10.3

Indicators in the display

You can use the status indicators in the display to ascertain general error causes; see chapter 3.3.3
"Display".
≤able 10.3:
Display
No Signal
Leuze electronic
configuration software, DIAGNOS≤ICS menu, and rectify the error.
Green/red LED – causes and measures
Possible cause
Warning message, e.g., weak recep-
tion signal
No object detected or reception signal
too weak
• No supply voltage connected to
the sensor
• Hardware error
Yellow LED – causes and measures
Possible cause
No object detected in the switching
range
Display indicators – causes and measures
Possible cause
Warning message, e.g., weak
reception signal
No object detected or reception sig-
nal too weak
Measures
Optimize object alignment
Position object in the measurement range
• Check supply voltage
• Contact Leuze electronic customer ser-
vice(see chapter 12 "Service and sup-
port")
Measures
Position object in the configured switching
range
Measures
Optimize object alignment
Position object in the measurement
range
ODS 10
≤roubleshooting
45

Advertisement

Table of Contents
loading

Table of Contents