Ac Voltage And Current Waveforms; Charging; Motor-Side Converter - ABB ACQ580-34 Hardware Manual

Drives for water
Hide thumbs Also See for ACQ580-34:
Table of Contents

Advertisement

1
1
LCL filter contactor
2
LCL filter
3
Line-side converter
4
DC capacitors
5
DC link

AC voltage and current waveforms

The AC current is sinusoidal at a unity power factor. The LCL filter suppresses the AC
voltage distortion and current harmonics. The high AC inductance smooths the line voltage
waveform distorted by the high-frequency switching of the converter. The capacitive
component of the filter effectively filters the high-frequency (over 1 kHz) harmonics.

Charging

Charging is needed to power up the DC link capacitors smoothly. Discharged capacitors
cannot be connected to the full supply voltage. The voltage must be increased gradually
until the capacitors are charged and ready for normal use. The drive contains a resistive
charging circuit consisting of fuses, contactor and charging resistors. The charging circuit
is in use after start-up until the DC voltage has risen to a predefined level.

Motor-side converter

The motor-side converter converts the DC back to AC that rotates the motor. It is also able
to feed the braking energy from a rotating motor back into the DC link. The motor-side
converter is controlled by a type CCU-24 control unit. This is called the drive control unit or
control unit in this manual.
2
Operation principle and hardware description 27