110 Technical data
Drive type
Frame size
ACQ580-34-
U
= 480 V
N
246A-4
293A-4
365A-4
442A-4
505A-4
585A-4
650A-4
Drive type
Frame size
ACQ580-34-
U
= 480 V
N
240A-4
302A-4
361A-4
414A-4
477A-4
U
Nominal voltage of the drive
N
Nominal input current (rms) at 40 °C (104 °F)
I
1
I
Maximum output current. Available for 10 seconds at start, otherwise as long as allowed by drive
max
temperature. 140% ... 200% of I
I
Continuous rms output current. No overload capability at 40 °C (104 °F). This is indicated in the
2
type designation label as output current I
P
Typical motor power in no-overload use
N
I
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes when parameter
Ld
97.02 Minimum switching frequency is set to 2 kHz or less.
P
Typical motor power for light-duty use
Ld
IEC RATINGS
Input
current
I
1
A
R11
209
R11
233
R11
307
R11
363
R11
363
R11
389
R11
441
UL (NEC) RATINGS
Input
current
I
1
A
R11
209
R11
258
R11
307
R11
363
R11
414
, depending on power rating.
Hd
Output ratings
Max.
current
I
max
A
350
418
498
621
631
751
859
Output ratings
Max.
current
I
max
A
306
408
513
614
704
.
2
Light-duty use
I
P
Ld
Ld
A
hp
240
200
260
200
361
300
414
350
414
350
430
350
483
400
3AXD00000586715
Light-duty use
I
P
Ld
Ld
A
hp
240
200
302
250
361
300
414
350
477
400
3AXD00000586715