176 Step-by-step drawings for an installation example in Rittal VX25 800 mm wide cabinet
1
3
2
Drive type
Air flow
Losses
ACQ580-34-
3
m
/h
W
U
= 400 V
N
246A-4
2100
5280
293A-4
2100
6400
363A-4
2100
8000
442A-4
2100
10000
505A-4
2100
10000
585A-4
2100
12600
650A-7
2100
14200
U
= 480 V IEC
N
246A-4
2100
5220
293A-4
2100
5220
365A-4
2100
7830
442A-4
2100
9135
505A-4
2100
9135
585A-4
2100
9135
650A-4
2100
10440
U
= 480 V UL
N
240A-4
2100
5280
302A-4
2100
6525
361A-4
2100
7830
414A-4
2100
9135
477A-4
2100
10440
(PE) PE (PE)
Type DIN 43653
2a
170M5408
170M5410
170M6410
170M6411
170M6412
PE
170M6414
170M6414
170M4410
170M5408
170M5410
ACQ580-34
170M6410
170M6411
170M6411
170M6412
170M4410
170M5408
170M5410
170M6410
170M6411
WARNING! The UDC+ and UDC- terminals of the drive
module must not be used for any other than optional
external brake chopper connection.
L2
L3
L1
2b
3
L1
L2
L3
1
8
L1/
L2/ L3/
UDC- UDC+
U1
V1
W1
INPUT
PE
OUTPUT
T1/
T2/
T3/
U2
V2
W2
9
6
7
4
V1
W1
U1
5
~
3
M

Advertisement