Overview - Heatshift Canopy - Valor LX1 Installation Manual

Hide thumbs Also See for LX1:
Table of Contents

Advertisement

Installation Planning
 WARNING
Ensure weight of wall above is
NOT carried by the appliance.
Easy vertical venting using
supplied 4 x 6-5/8" coaxial
outlet and two 45° elbows (not
included) or vent through wall
1/2" thick non-combustible
cement board required above
bottom of window
Sheet metal structure to sup-
port non-combustible fi nishes
This space is not a shelf
1/2" thick non-combustible
cement board required from
bottom of window to 11-1/4"
above fi replace top (not
supplied)
Combustible wall fi nish up
to 1-1/4" thick allowed below
opening. Combustible projec-
tions must otherwise be kept
min. 4" below opening.
Steel pedestal (optional, not
included) or wood base al-
lowed but not required
 WARNING
Some materials or items, although safe,
may discolor, shrink, warp, crack, peel, and
so on because of the heat produced by the
fireplace. Avoid placing candles, paintings,
photos, and other items sensitive to heat
around the fireplace.
12

Overview - HeatShift Canopy

For installations that do not extend vertically all the way to the ceiling, the
HeatShift Canopy kit (2100HSC) allows the installer to install the fi replace
and off set the HeatShift system to the side, maintaining visual space above
the fi replace. Refer to the Installation Manual for this kit for more details.
HOT WALL SURFACES! The walls directly
above the fireplace are constructed of non-
combustible materials and, although safe,
may reach temperatures in excess of 200°F
(93°C) depending on choice of materials. Do
not touch. Finish the walls using materials
suitable for these temperatures.
 WARNING
Top HeatShift discharge (min.
2-1/2" clearance below ceiling)
Variable total installation
height by raising top enclosure
HeatShift fl ex pipes to top
outlet (two 5" Ø)
Vertical components are fi xed
to wall with mounting studs
(wood)
HeatShift canopy collects and
redirects hot convected air to
the side into two 5" Ø pipes
Remote Battery and
Wall Switch Kit (re-
quired and supplied)
c/w 35' wire length
Remote control hand-
set wall holder, to be
mounted min. 3' away
from fi replace opening
2100P heater

Advertisement

Table of Contents
loading