Re-Installing Windows - Valor LX1 Installation Manual

Hide thumbs Also See for LX1:
Table of Contents

Advertisement

Installation
Window Re-installation
1. Remove any fuel bed media from the window bottom
rail before installing the window.
2. Ensure the braided gasket is well fi tted to the bottom
of the window.
3. Insert the window behind the appliance's front panel,
making sure the angled rail at the top is facing out.
4. Lower the bottom of the window into the bottom rail.
5. Push the top of the window pane against the fi rebox.
Ensure it is centered on the fi rebox so it seals prop-
erly against the end window.
Bottom railing
6. Pull one retainer hook over the angled rail at the top
of the window, and hook it down completely. Repeat
on the other side. Make sure the hooks latch com-
pletely to the rail.
Correct
7. Repeat steps 1 to 6 for the other side window.
8. Pull the top of each window to ensure it the spring
mechanisms are working well and pull the window
back into position.
48
Out
Incorrect

Re-installing Windows

9. Apply fi rm hand pressure around the window panes
(particularly on the top and sides). ENSURE THE
FRONT WINDOWS SILICONE GASKETS ARE WELL
SEALED, FROM TOP TO BOTTOM, TO THE SIDE WIN-
DOWS!
10. Replace the hot glass warn-
ing plate against one of the
side windows, in the bottom
rail.
11. When fi nished, replace barrier screens onto fi replace.
 WARNING
The window units must be correctly
installed, fastened and sealed after
servicing. If not it could result in serious
bodily injury and/or damage to the
fireplace.
To ensure safe operation:
• Double-check that the bottom of each
window frame is correctly installed in the
bottom support railing;
• Verify that the retainer hooks are properly
fastened to the top angle brackets;
• Pull out the top of each side window and
release it to ensure the springs return it;
• Ensure the window is sealed before
operation.
For safety purposes, make sure the barrier
screen is re-installed on the fireplace front
after maintenance.
 WARNING
Failure to install the window correctly can:
• Cause carbon monoxide to leak.
• Affect the performance of the fireplace.
• Damage components.
• Cause overheating resulting in dangerous
conditions.
Damage caused by incorrect window
installation is not covered by the Valor
Warranty.

Advertisement

Table of Contents
loading

Table of Contents