Standard Emulation; Ipcl Codes; Epos Emulation; Microline Emulation - Ithaca 150 Programmer's Manual

Receipt/validation/journal printers
Table of Contents

Advertisement

Programmer's Guide
In many cases, applications require that control sequences be specified in hexadecimal or decimal
codes. In most cases, commands are specified in ASCII, hexadecimal, and decimal. The table in
Appendix B lists ASCII, decimal, and hexadecimal equivalents.

Standard Emulation

The standard control codes for the Series 150 Printer are extensions and subsets of the IBM
emulation provided on other PcOS products. In all cases, an application designed for a Series 50
Printer with IBM code sets will function with a Series 150 printer. There are, however, more
features in the Series 150 Printer that can be used for new applications.

IPCL Codes

IPCL (Ithaca Printer Control Language) codes are designed to control a printer without using
control characters, i.e., characters less than 20H. Only the standard emulation supports IPCL.
Not all commands are supported by IPCL codes. For those commands that are, the IPCL code is
listed.
In rare cases, an IPCL code will interfere with the text that is to be printed. The IPCL translator
can be disabled with an [ESC] y <4> command.

EPOS Emulation

5
ESC/POS
is referred to here as EPOS. The Series 150 Printer supports an EPOS emulation with
extensions. The emulation is designed to allow the Series 150 Printer to be used with applications
that are designed for Seiko Epson printers. It is intended that the standard emulation be used for
new applications. Not all of the features of Series 150 Printers are supported by EPOS.
This manual will include the EPOS code equivalent for features of the Series 150 Printer that are
supported by EPOS. When EPOS commands are significantly different from the standard
emulation, an independent EPOS description is provided.

Microline Emulation

The standard control codes for the Series 150 Printer are extensions and subsets of the Microline
emulation provided on other PcOS products. In all cases, an application designed for a Series 50
Printer with Microline 150 Printer that can be used for new applications.

Star Emulation

The standard control codes for the Series 150 Printer are extensions and subsets of the Star
emulation provided on other PcOS products. In all cases, an application designed for a Series 50
Printer with Star code sets will function with a Series 150 Printer. There are, however, more
features in the Series 150 Printer that can be used for new applications.
5
ESC/POS is a registered trademark of the Seiko Epson Corporation.
12/14/99
PcOS Series 150
Rev G
Control Codes Overview
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcos 150 series151152153154