Ithaca 150 Programmer's Manual page 77

Receipt/validation/journal printers
Table of Contents

Advertisement

Programmer's Guide
Function
ASCII
Hexadecimal
Decimal
Function
Response
Where
12/14/99
PcOS Series 150
Inquire printer ID
[ENQ] <21>
05H 15H
<5> <21>
Returns printer IEEE 1284 ID string
Serial/Parallel, IEEE1284
[ACK] <21> <n> {ID string}
<21> is the echo of the command ID.
<n> = number of return bytes in the ID string
{ID string} is the IEEE 1284 ID return string, which is as follows:
MFG:Ithaca-Periph.;
CMD:M150CL,IPCL;
CLS:PRINTER;
MDL:S150 PcOS;
DES:Ithaca-Peripherals Series 150;
REV:01.00;
OPTS:$51xy
Where x is a bit field defined as follows:
Bit 0 = Alternate print zone
Bit 1 = 0 not defined
Bit 2 = 0 not defined
Bit 3 = Always 0
Bit 4 = Always 1
Bit 5 = Always 1
Bit 6 = Always 0
Bit 7 = Always 0
and y is a bit field defined as follows:
Bit 0 = Slip capability
Bit 1 = Knife installed
Bit 2 = MICR installed
Bit 3 = Always 0
Bit 4 = Always 1
Bit 5 = Always 1
Bit 6 = Always 0
Bit 7 = Always 0
Rev G
Control Codes
Printer Status Set/Inquire
Parallel, non-IEEE 1284
Not supported via PE