12. Check the checkbox for [Channel No.] to set the items referring to the table shown
below.
[Sensor
Name]
[Data Type]
[Details]
13. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
1.4.5

Antenna unit configuration

Do the procedure here to set the antenna unit.
1. Click [Radar Sensor] on the menu bar.
2. Confirm that the Equipment ID checked at the [Own Ship Setting] menu (see
section 1.3) is activated.
3. Click the [Details] button to show the [Details Setting] window.
Item
Enter an appropriate name that indicates sensor's function.
Sets the input data type. Setting range: -10-10V, 0-10V, 4-20mA.
Note: For [4-20mA], fix the jumper to the connector (J3 to J5). See
the installation manual of chart radar.
• [Sensor Type No.]: Enter
the sensor type.
• [Data Name]: Enter the
appropriate data name.
• [Calibration Active]:
Check the check box to
display the analog input
data on the conning dis-
play and show the lower
columns.
• [Calibration Point1(2)]:
Enter input voltage (or
current).
• [Calibration Point Value1(2)]: Enter the value to show on the
conning display. In the example above, the conning display
shows "0" for 0V; "120" for shown for 10V.
Note: For input current, enter the value in ampere units (A).
1. INITIAL SETTING AND ADJUSTMENT
Remarks
1-27