Double Doors; General Adjustment - Assa Abloy Besam SW200i US Installation And Service Manual

Swing door operator
Table of Contents

Advertisement

13.2.2

Double doors

For double doors, the MASTER door must be learned first and thereafter the SLAVE door.
When the SLAVE door is learned, the MASTER door will open up to fully open position during
the learning phase of the SLAVE door.
The doors can also be learned separately before connecting the sync cable. In case of astragal
doors and separate learning, the MASTER door must be held open before the SLAVE door
learn is carried out.
13.3

General adjustment

a Set the hold open time with the potentiometer on the control unit.
b Adjust the opening speed (OPSP) to comply with ANSI A156.19. Turning clockwise increases
the speed (see Table I on page 79).
c Adjust the closing speed (CLSP) to comply with ANSI A156.19. Turning counter- clockwise
decreases the speed (see Table I on page 79).
d Connect the required activation units.
e Check that the installation complies with AHJ (Authority Having Jurisdiction).
1007718-US-3.0
Issue 2012-06-27
13 Start-up
63