11 Mechanical installation
11
Mechanical installation
11.1
Surface mounted installation
The operator is mounted on either side of the door header with two available spindle locations,
Standard 3 3/4" (95 mm) and High performance 8 1/4"(210 mm) between hinges and outgoing
shaft, depending on type of doors.
The Standard installation is best suited according to ANSI / BHMA A156.19 and ADA 28 CFR
Part 3. The High performance installation is used in windy environments, when heavy doors
are used and when there are big differences in pressure.
The door is controlled with a push or pull arm system.
Note: Consider all power wire entry locations and signaling wires before preparing back plate.
Standard 3 3/4" (95 mm)
A
B
C
A
5 1/2" (140 mm)
B
28 9/16" (725 mm)
C
28 5/8" (726 mm)
11 /
3 /
3
4"
1
16"
30
High performance 8 1/4" (210 mm)
A
C
A
B
C
11 /
1
16"
Issue 2012-06-27
B
10" (255 mm)
28 3/8" (720 mm)
1 3/8" (36 mm)
1 /
8
4"
1007718-US-3.0