Fastening requirements

Base material
Steel
Aluminium
Reinforced concrete
Wood
Brick wall
* Besam minimum recommended requirements. Building Codes may give different specifications.
Refer to AHJ (Authority Having Jurisdiction).
** Thinner wall profiles must be reinforced with rivnuts.
10.5

Tools required

Metric Allen keys 3; 4; 5 and 6 mm
Tool for screw between cover and backplate (?)
Flatblade screwdriver (potentiometer and terminal size)
Screwdriver (Philips size 2)
Nut driver, 5 mm
Tape rule
Power drill and set of drill bits
Center punch
Wire stripper
Silicone sealant
Installation and Service Manual (this manual)
10.6

Installation on double doors

If the operators are to be mounted at the same height with pushing and pulling arm systems, the
height is determined by the pulling arm system, PULL. The pushing arm system PUSH must
always have a shaft extension, minimum 2" (50 mm), maximum 2 3/4" (70 mm) to match the
mounting heights visually.
Example: if PULL has a 3/4" (20 mm) extension, the PUSH must have a 2 3/4" (70 mm) exten-
sion. If PULL has 0" mm extension, the PUSH must have a 2" (50 mm) extension.
For installation, follow the instructions for the applicable arm system.
1007718-US-3.0
Minimum requirements of wall profile*
3/16" (5 mm)**
1/4" (6 mm)**
min. 2" (50 mm) from the underside
2" (50 mm)
Expansion-shell bolt, min. M6x85, UPAT PSEA B10/25, min.
2" (50 mm) from the underside
Issue 2012-06-27