20 ANSI / BHMA A156.19 (LOW ENERGY APPLICATION)
Table II
Total Opening Time to 90 Degrees
Backcheck at 60 degrees
Table I plus 2 seconds
If the door opens more than 90 degrees, it shall continue at the same rate as backcheck speed.
Note: To determine maximum times from close to full open, the operator shall be adjusted as
shown in the chart. Back check occurring at a point between positions in Table II shall use the
lowest setting. For example, if the backcheck occurs at 75 degrees, the full open shall be the
time shown in Table I plus 1.5 seconds.
20.1.5
Signage
Doors shall be equipped with signage visible from either side, instructing the user as to the op-
eration and function of the door. The signs shall be mounted 50" +/- 12" (1270mm +/- 305mm)
from the floor to the center line of the sign.
The letters shall be 5/8 inch (16 mm) high minimum.
Doors All doors shall be marked with signage visible from both sides of the door, with the
words "AUTOMATIC CAUTION DOOR" (see illustration below). The sign shall be a minimum
of 6 inches (152 mm) in diameter with black lettering on a yellow background. Additional in-
formation may be included.
Additionally one of the following knowing act signs shall be applied:
When a Knowing Act Switch is used to initiate the operation of the door operator, the doors
shall be provided with signs on both sides of the door with the message "ACTIVATE SWITCH
TO OPERATE". The lettering shall be white and the background shall be blue.
When push/pull is used to initiate the operation of the door operator, the doors shall be provided
with the message "PUSH TO OPERATE" on the push side of the door and "PULL TO OPER-
ATE" on the pull side of the door. The lettering shall be white and the background shall be blue.
80
Backcheck at 70 degrees
Table I plus 1.5 seconds
C L
Issue 2012-06-27
Backcheck at 80 degrees
Table I plus 1second
Apply to both sides of the door.
When using a wall switch,
apply to both sides of the door.
Apply the push decal to the push
side and the pull decal to the pull
side of the door.
Push plate
PRESS
TO OPEN
1007718-US-3.0