D6001DE-L Series Double Egress Power Operator Unit

Prepare Frame and Doors

Become familiar with operator components and fasteners. It is recommended that components remain in boxes until
installed. Verify there is minimum ceiling clearance for operator installation before proceeding. (Figure 1)
A. Prepare frame.
1. Verify correct installation. (Figure 2)
NOTE: These instructions are for Pair of
Doors, where door on right is a Push door
and door on left is a Pull door. Arms included
with this assembly will fail if both doors are
Pull doors or if both doors are Push doors.
Please contact Customer Service or your
local distributor if this is the case.
2. Frame header MUST be flat / without twists.
Backplates can be used as reference.
NOTE: If frame is not flat or is twisted,
additional steel back plates or shimming is
required. Failure to mount units properly can
result in improper function of operator or
OR
inability to snap on covers.
3. Mark center of opening on frame header
between jambs.
4. Using chart, mark from center of opening to
left. (Figure 3)
NOTE: Template provided on page 16.
5. Measure 1" up from frame rabbet and mark
at Dim A and Dim B locations.
6. Drill holes.
7. Using supplied backplate screw pack in
Box 1, insert screws into prepared mounting
holes.
For Metal Frame: Use two (2) 1/4-20 x 1" flat
head machine screws.
For Wood Frame: Use two (2) #14 x 1-1/2" oval
head self-drilling screws.
NOTE: Do not tighten mounting screws at
this time. Leave 5/16" minimum (thickness of
backplate) between frame face and back of
screw head.
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1048-020 Rev 1 01/23
Approved 2023-11-10
Figure 1
Push Side
Pull Side
Right Hand
PULL
Figure 2
Dim B
Dim A
1"
Door Size
Dim A
Pair of 36" doors:
5-9/16" (141mm)
Pair of 38" doors:
7-9/16" (192mm)
Pair of 40" doors: 9-9/16" (243mm)
Pair of 42" doors:
11-9/16" (294mm)
Pair of 44" doors:
13-9/16" (344mm)
Pair of 46" doors:
15-9/16" (395mm)
Pair of 48" doors: 17-9/16" (446mm)
Figure 3
Left Hand
PULL
Center of Opening
Dim B
30-9/16" (776mm)
32-9/16" (827mm)
34-9/16" (878mm)
36-9/16" (929mm)
38-9/16" (979mm)
40-9/16" (1030mm)
42-9/16" (1081mm)
5